立加報警說明 | ||
號碼 | 英文注釋 | 中文注釋 |
2001 | OP EMERGENCY PB OR LS OFF | 急停開關被按下或軸向限位開關被碰到 |
2002 | MAIN SPINDLE SERVO ALM | 主軸伺服報警 |
2003 | CIRCUIT PROTECT TRIP | 電路保護故障 |
2004 | HYD。PUMP MOTOR OVERLOAD | 液壓馬達過載 |
2005 | HYD。PRESSURE DOWN ALARM | 液壓壓力低報警 |
2006 | HYD。PUMP MOTOR NOT RUN | 液壓馬達沒有運轉 |
2007 | SPINDLE STOP SIGNAL ALARM | 主軸停止信號報警 |
2008 | GEAR SHIFT CHECK SW。ALARM | 換擋檢測開關報警 |
2009 | MAGAZINE EMG。STATUS | 刀庫急停 |
2011 | MAIN POWER PHASE&ATC SWITCH ER | 總電相序或ATC開關錯誤 |
2015 | SPINDLE TOOL UNCLAMP ALARM | 主軸松刀報警 |
2017 | SPINDLE HEAD OIL OVERFLOW | 主軸冷卻油過溢 |
2020 | CLT.&LUB&ATC.MOTOR OVERLOAD | 冷卻,潤滑,或ATC馬達過載 |
2021 | AIR PRESSURE DOWN ALARM | 氣壓低報警 |
2022 | SPINDLE ORINETATION OVERTIME | 主軸定位超時 |
2023 | M06 COMMAND OVERTIME ALARM | M06命令超時報警 |
2024 | T.CODE COMMAND ERROR | T碼命令錯誤 |
2025 | TOOL NO.SELECT KEEP/R NOT SET | 刀具號選擇保持開關沒有設定 |
2026 | GEAR SHIFT OVERTIME ALARM | 換擋超時報警 |
2027 | SPDL SPEED ARRIVAL ALARM | 主軸速度到達報警 |
2028 | SPINDLE ROTATION MALFUNCTION | 主軸旋轉故障 |
2029 | APC DOOR OPEN | APC門被打開 |
2030 | TOOL CHANGE MOTOR BRAKE RLS | 換刀馬達剎車釋放 |
2031 | ATC MAINTENANCE STATUS INT | ATC維護狀態 |
2032 | EXTERNAL FEED HOLD (OP PB SW) | 外部速率保持 |
2033 | SPINDLE HEAD OIL PUMPING ALARM | 主軸冷卻油泵報警 |
2034 | CLNT W/TANK OR LEVEL SW ALARM | 冷卻液水位低報警 |
2035 | TSC W/TANK MOTOR OVERLOAD | TSC冷卻馬達過載 |
2036 | TOOL SEARCH ILLEGAL ALARM | 刀具搜索違法報警 |
2037 | M06 COMMAND ILLEGAL ALARM | M06命令違法報警 |
2039 | MAG.MOVING ILLEGAL POS.ALARM | 刀庫移動錯誤位置報警 |
2043 | 4-AXIS PRESSURE DOWN CHECK AL | 第四軸壓力低檢測報警 |
2045 | FIXTURE CLAMP/UNCLAMP ALARM | 夾具夾緊放松報警 |
2047 | ATC DOOR OPEN | ATC門被打開 |
2048 | OPERATORS SIDE DOOR OPEN | 操作門被打開 |
2050 | LUB.LEVEL LOW OR PRESSURE DOWN | 潤滑油位低或壓力低 |
2051 | OIL COOLING UNIT ALARM | 油溫冷卻器報警 |
2052 | COOLANT FILTER CHANGE ALARM | 冷卻過濾器轉換報警 |
2053 | COOLANT PRESSURE DOWN ALARM | 冷卻液壓力低報警 |
2054 | TOOL LIFE MANAGE MENT END ALARM | 刀具壽命結束報警 |
2058 | PARTS COUNT END ALARM | 工件計數結束報警 |
2060 | SPINDLE TOOL CL/UNCL ALARM | 主軸刀具夾緊/放松報警 |
2061 | TMG STOPPER IN/OUT ALARM | 刀庫停止器進出報警 |
2062 | ATC CHANGER POS. ALARM | ATC 換刀位置報警 |
2063 | SAFETY SWITCH LOCKING ALARM | 安全開關鎖定報警 |
2064 | WAIT.POT(MAG) SPD/MAG.SIDE AL | 刀庫等待刀杯到主軸側/刀庫側報警 |
2065 | CHANGER ARM POS.CHECK ALARM | 換刀臂位置檢查報警 |
2066 | MUST BE COMMAND NEXT TOOL No. | 必須指定下一個刀號 |
2068 | ATC DOOR OPEN /CLOSE ALARM | ATC門開/關報警 |
2074 | ATC OVERTIME ALARM | ATC超時報警 |
2075 | ATC MAGAZINE ROT.OVERTIME ALARM | ATC 旋轉超時報警 |
2077 | 4TH-AXIS CL/UNCL SW.ALARM | 第四軸夾緊放松開關報警 |
2079 | TOOL MAG.SYNCHRO MALFUNCTION | 刀庫同步故障 |
2080 | ATC INTERLOCK ALARM | ATC 互鎖報警 |
2081 | ATCMAGAZINE GUARD DOOR OPEN | ATC 刀庫門開報警 |
2082 | ATC MAG.POT TOOL OUT SW.ALARM | 刀庫刀杯出來報警 |
2083 | ATC MAINTENANCE STATUS | ATC維護狀態 |
2084 | APC SET-UP STATION DOOR OPEN | APC安裝站門開 |
2085 | THERMAL COMPENSATION ERROR | 熱補償錯誤 |
2087 | GEAR SHIFT LOST | 檔位丟失 |
2088 | TOOL BREAKAGE | 刀具破損 |
2089 | TOOL WEAR DETECT | 刀具磨損檢測 |
2090 | PALLET UNCLAMP STATUS | 工作臺放松中 |
2094 | CHIP OR SCREW CONVEYOR ALARM | 排屑機報警 |
2099 | DRUM FILTER CHIP CLT.LOW LEVEL | 鼓式過濾器液面低 |
2101 | MUST BE RETUREND TO REF.POINT | 必須返回原點 |
2102 | CYCLE START IN FIXTURE UNCLAMP | 夾具放松時的循環啟動 |
2103 | MUST BE ATC 1 CYCLE | ATC必須循環一次 K12.4=1 |
2104 | SPINDLE TOOL No .ZERO | 主軸刀號為0 |
2105 | ATC OP MAUAL MODE | ATC手動模式 |
2106 | APC OP MAUAL MODE | APC手動模式 |
2107 | FEEDRATE OVERRIDE 0% | 進給倍率選擇開關為0 |
2108 | AUTO POWER OFF READY | 自動電源關準備中 |
2109 | MACHINE LOCK ON STATUS | 機床鎖定中 |
2110 | AUXILIARY FUNC.M,S,T,LOCK ON | 輔助機能,即M,S,T鎖定中 |
2111 | APC SET-UP SW.UNPUSH | APC設定按扭沒有按下 |
2112 | MAN AXIS MOVING INTERLOCK | 手動軸移動互鎖 |
2113 | SPDL STOP IN CUTTING MODE CMD | 切削模式主軸停 |
2114 | RST COMMAND ALARM ON STL | 復位命令報警 |
車床報警說明 | ||
序號 | 英文注釋 | 中文注釋 |
2001 | The Emergency push button s/w is pressed. The X or Zaxis multi-limit s/w is tripped out. | 急停按鈕被按下或X,Z軸限位開關被壓下 |
The x or z axis multi-limit switch is tripped out. | X,Z軸限位開關被壓下 | |
2002 | The 1st spindle is in the Emergency status(It comes out when a 1st spindle alarm occurs) | 第一主軸在急停狀態(主軸在報警狀態此報警出現) |
2003 | The control circuit protectors are tipped out or fuse blown | 空氣開關跳脫或保險絲熔斷 |
2004 | The hydraulic motor is overloaded | 液壓馬達過載 |
2005 | The hydraulic pressure becomes below the set value.. | 油壓壓力在設定值以下 |
Trouble of hydraulic pressure s/w | 油壓壓力開關故障 | |
2007 | The zero-speed detection or the speed detection of spindel motor is not detected. | 主軸馬達零速檢測器或速度檢測器無檢測 |
2008 | Fault of gear shift confirmation switch. | 換擋開關出錯 |
2009 | The 2nd spindle Emergency status.(It comes out when a 2nd spindle alarm occurs) | 第2主軸在急停狀態(2主軸在報警狀態此報警出現) |
2010 | Machine is in Not Ready status. | 機床準備不足狀態 |
2012 | The X-axis torque limiter s/w is tripped out. | X軸扭力開關被絆住 |
Trouble of x-axis torque limiter switch | X軸扭力開關出錯 | |
2013 | The Z-axis torque limiter s/w is tripped out. | Z軸扭力開關被絆住 |
Trouble of z-axis torque limiter switch | Z軸扭力開關出錯 | |
2014 | The B-axis torque limiter s/w is tripped out. | B軸扭力開關被絆住 |
Trouble of B-axis torque limiter switch | B軸扭力開關出錯 | |
2017 | The hydraulic oil of drain oil reservoir is overflowed. | 液壓蓄油池過溢報警 |
Trouble of float switch in the oil reservoir | 液壓蓄油池過溢出錯 | |
2019 | Keep relay setting to define the machine model is not selected | 關于機床種類的K參數沒有設定 |
2020 | The AC motor is overloaded.(coolant or lubrication pump motor) | 馬達過載(冷卻馬達或潤滑油馬達) |
2021 | The Torque limit SKIP command is used incorrectly. | 使用扭力限制跳過命令出錯 |
2022 | The spindle orientation command (m19) is not accepted. | 主軸定位命令沒有執行 |
2023 | The tool change command is not accepted. | 換刀命令沒有執行 |
2024 | Incorrect tool No.is commanded. | 錯誤的刀浩命令 |
2025 | Keep relay setting to define the tool post model is not selected | 控制刀塔型號的K參數沒有設定 |
2026 | The gear shift command(M41/M42/M43/M44)is not accepted | 換擋命令沒有執行 |
2027 | The spindle speed arrival signal is not detected. | 主軸速度抵達信號出錯 |
2028 | Spindle rotation command(M03/M04)is not accepted. | 主軸旋轉命令沒有執行 |
2029 | The splash guard door is opened | 防濺門開 |
Trouble of door interlock limit switch | 門互鎖限制開關故障] | |
2030 | Machine Lock command(M17/M18)is commanded in the improper mode. | 在不正確的模式執行機床鎖定指令 |
2031 | The reference point return is not completed. | 原點復歸沒有完成 |
2032 | In auto mode ,FEED HOLD status | 自動模式下進給保持 |
2033 | Air pressure becomes below the set value | 氣壓在設定值以下 |
Trouble of Air pressure limit switch | 氣壓限位開關故障 | |
2034 | Proximity switch to detect the chucking confirmation is at a wrong position. | 卡盤夾緊近接確認開關位置錯誤 |
Trouble of chucking confirmation limit switch | 卡盤夾緊近接確認開關故障 | |
2035 | The axis change command is not accepted | 軸轉換命令沒有執行 |
2036 | Chuck clamp/unclump command (M68/M69) is not accepted. | 卡盤夾緊/放松命令沒有執行 |
2037 | Proximity switch to detect the tailstock quill confirmation is at a wrong pos | 尾座套筒位置檢測開關位置錯誤 |
Tailstock quill operation command (M78/M79)is not accetted | 尾座套筒伸出/收回命令沒有執行 | |
Trouble of tailstock quill confirmation switch | 尾座套筒位置檢測開關故障 | |
2038 | The Programmable Tailstock command(M46/M47) IS NOT accepted | 可程式尾座命令沒有執行 |
2039 | The part catcher command(M10/M11) is not accepted | 工件收集器指令沒有執行 |
2040 | The bar-feeder command(M50/M51) is not accepted | 棒料送料器指令沒有執行 |
2041 | The alarm occurs at the Bar-feeder side. | 棒料送料器出現報警 |
2042 | The Auto door operation command (M52/M53)is not accepted | 自動門指令沒有執行 |
2043 | The steady rest operation command (M38/M39/M58/M59) is not accepted | 中心架指令沒有執行 |
2044 | The part catcher is advanced,even though M10 is not commanded | 即使M10沒有指令,零件收集器也伸出 |
2045 | The Quick tool setter operation command(M80/M81)is not accepted. | 對刀儀命令沒有執行 |
2046 | The chuck is opened,even though M69 is not commanded | 即使M69指令沒有執行,卡盤還是打開 |
2047 | The encoder signal error for turret positioning is detected | 刀塔旋轉指令編碼器檢測錯誤K5.4刀塔松開 |
2048 | The reset (RST)command is used while program is running | 程序運轉中使用復位指令 |
2049 | The C-axis operation command(M88/M89/M90)is not accepted | C-軸松緊指令沒有執行 |
2050 | Lack of lubrication oil. | 缺潤滑油 |
2051 | Lack of coolant oil. | 缺冷卻液 |
2052 | Trouble of proximity switch to detect chucking confirmation | 卡盤夾緊近接確認開關故障 |
2053 | Revolving tool is not engaged | 旋轉刀具使用中 |
2055 | Synchronous command(M203/M204)is used in the improper condition | 同步運轉指令使用不恰當 |
2056 | The M-codes for main and sub-spindle rotation,without M206 between those commands,is consecutively used. | 主軸和副主軸的M碼使用問題 |
2057 | The tool life is reached at its expectancy | 刀具壽命超出設定范圍 |
2058 | The parts counting is reached at the limit value set | 工件記數超出設定范圍 |
2060 | The cycle start command is invalid because the chuck is not in clamp | 卡盤沒有夾緊就執行循環啟動 |
2062 | Trouble of the limit switch to detect the programmable tailstock operation | 可編程尾座限位開關故障 |
2063 | Trouble of proximity switch to detect the quick tool setter operation | 對刀儀運轉檢測開關故障 |
2090 | The feedrate value (f0%)srtter error | 被率設定為0錯誤 |
2093 | The reference point return is commaned,thougH each axis is alreAdy at its reference position | 執行原點復歸指令,可是各軸已經在原點位置 |
2096 | The feedrate override is 0% | G01被率開關設定為0 |
2097 | The machine lock status | 機床鎖定狀態 |
2098 | The M00/M01 command status . | M00/M01狀態 |
2099 | The M02/M30 command status . | M02/M30 狀態 |
2061 | 安全門鎖鑰匙孔處處于打開狀態,鑰匙向左旋 |
報警表 | ||
1:緊急停止 | ||
編號 | 內容 | 恢復 |
AL01 | 緊急按鈕或限位開關關閉 | |
控制板上某個急停按鈕被按下。 | 釋放急停按鈕開關 | |
某個X軸,Y軸,Z軸的急停限位開關被按下。 | 用超程釋放法解除限位開關 | |
短路/按鈕開關或限位開關故障。 | 檢查線路 | |
AL02 | 主軸系統報警,主軸系統出現異常。 | 參照主軸伺服系統說明書。 |
AL03 | 電路保護裝置斷路 | |
電路保護裝置(QF21,QF22,QF23,QF24)斷路 | 檢查控制電源(AC,DC)及電路 | |
短路 | 重置控制電源 | |
AL04 | 液壓泵電機過載 | |
液壓泵或主軸箱潤滑油泵的電機過載 | 檢查電機和過載繼電器 | |
檢測過電流的微型繼電器誤動作 | ||
短路 | 檢查電路 | |
AL05 | 液壓壓力下降(選項) | 檢查液壓動力裝置 |
液壓壓力低于壓力開關的設定值。 | ||
AL06 | 液壓泵電機不轉 | 檢查磁性繼電器 |
液壓泵電機的磁性繼電器故障 | ||
AL07 | 主軸停止信號故障 | 參照主軸伺服系統說明書。 |
AL08 | 齒輪速比范圍檢驗開關故障 | 檢查限位開關(SL12.SL13.SL14) |
主軸變速檢測開關誤動作 | ||
短路 | ||
AL11 | 主電源相序報警 | 檢查電源連接 |
電源相序錯誤 | ||
AL15 | 主軸松刀報警 | 檢查限位開關 (SL11) |
主軸松刀限位開關故障 | ||
短路 | ||
AL17 | 主軸冷卻油溢出 | 檢查回流油泵和油位開關(SV11) |
主軸內油位高于設定位置。 | ||
油位開關故障 | ||
AL19 | 機床型號的K參數沒有設定 | 檢查機床的型號和設定的K參數是否一致 |
設定正確的K參數 | ||
2:循環停止 | ||
AL20 | 冷卻泵或潤滑油泵馬達過載 | 檢查繼電器和馬達 |
冷卻泵或潤滑油泵馬達過載 | ||
過電流檢測繼電器故障 | ||
短路 | ||
AL21 | 氣壓低報警 | 檢查氣源和氣源管路 |
氣壓低于開關(SP12)的設定值 | ||
AL22 | 主軸定角度超時 | |
M19指令后,主軸定角度沒有在15秒內完成 | 檢查相應參數的設定值 | |
AL22 | 主軸定角度參數錯誤 | 檢查位置編碼器和電纜 |
主軸定角度編碼器或其反饋電纜故障 | 重新調整定向 | |
AL23 | M06指令超時 | 根據ATC的交換順序檢查每一步的開關信號 |
M06指令后,換刀沒有在30秒內完成 | ||
Y,Z軸的基準點信號或ATC的限位開關故障 | ||
AL24 | T代碼指令錯誤 | 復位并輸入正確的刀號 |
T指令 | ||
指令的刀號比主軸刀號相同 | ||
指令的刀號超出了刀庫的最大容量號 | ||
AL25 | 刀庫型號的K參數沒有設定 | 設定正確的K參數 |
40把刀:D486-B3/K6-B3(FANUC 0M/16M,18M) | ||
60把刀:D486-B4/K6-B4 | ||
90把刀:D486-B5/K6-B5 | ||
120把刀:D486-B6/K6-B6 | ||
AL26 | 主軸換檔超時 | |
換檔沒有在20秒內完成 | 檢查齒輪,換檔油缸等相關零件 | |
限位開關或電磁閥故障 | 檢查開關,閥(SL12,SL13,SL14,YV14,YV15 | |
短路 | ||
AL27 | 主軸轉速抵達超時 | 檢查相關零件 |
指令轉速20秒內沒有檢測到 | ||
主軸旋轉參數輸入錯誤 | 參看主軸系統說明書 | |
傳動機構到達信號故障 | ||
AL28 | 主軸旋轉故障 | |
沒有輸入S碼或S碼指令為0 | 輸入正確的S碼 | |
在不能使用的情況下,如主軸松刀狀態指令轉速 | 檢查主軸的當前狀態 | |
AL30 | 換刀馬達剎車釋放 | 操作完畢關閉其切換開關 |
馬達剎車釋放是為了旋轉馬達 | ||
AL31 | 必須返回原點 | 執行手動原點復歸 |
關電再開,或機床鎖定解除后,沒有返回原點就執行循環啟動指令 | ||
AL32 | 外部進給保持(操作面板按下了按鈕開關) | |
主操作面板循環停止按鈕被按下 | 檢查按鈕開關或線路 | |
短路 | ||
AL33 | 刀具破損檢測 | 檢查主軸刀具 |
檢測到刀具破損 | ||
AL34 | 外部冷卻單元報警 | 檢查外部冷卻單元 |
外部冷卻單元故障 | ||
AL36 | T指令的不合理位置 | |
在不能使用的位置發出刀具搜索指令 | 檢查ATC的狀態及相關零件 | |
與ATC有關的開關發生故障 | ||
電磁閥故障 | ||
短路 | ||
AL37 | M06指令的不合理位置 | |
等待刀座沒有在主軸側時發出M06指令 | 檢查ATC的狀況及相關零件 | |
AL37 | 與ATC有關的開關發生故障 | 檢查ATC的狀況及相關零件 |
電磁閥故障 | ||
短路 | ||
AL38 | X軸APC交換位置開關報警 | 檢查限位開關(SL63) |
托盤已經返回第一原點但APC位置開關還是關閉 | ||
限位開關或電磁閥故障 | ||
AL41 | APC 超時 | |
工作臺交換沒有在150秒內完成 | 檢查APC順序和有關零件 | |
限位開關或電磁閥故障 | ||
AL42 | M61/M62命令在錯誤位置 | APC返回初始位置 |
操作APC時不在初始位置 | ||
AL45 | B軸命令錯誤(包含小數點) | 重新執行 |
B軸沒有在適當的位置夾緊 | ||
AL47 | ATC門開 | 關閉ATC門 |
ATC門關開關(SL56)關閉狀態 | ||
ATC門處于打開狀態 | ||
AL48 | 操作者一側的開著 | 關門 |
操作者一側的開著 | ||
開關故障 | ||
AL49 | 請關閉NC電源再開 | |
轉動鎖定狀態的B軸出現的報警 | 請關閉NC電源再開 | |
AL50 | 潤滑油油位降低或壓力下降 | |
潤滑油不足 | 加注潤滑油 | |
油位開關故障 | 檢查開關 | |
AL51 | 油溫冷卻器故障 | 參照油溫冷卻器說明書 |
AL52 | 主軸中心出水過濾網需要更換 | 更換過濾網 |
過濾器檢測開關被激活 | 檢查開關 | |
AL53 | 冷卻液壓力低報警 | 檢測T-S-C裝置 |
在T-S-C操作中壓力低 | ||
AL55 | 循環啟動中復位報警 | 檢查坐標系并再次執行此操作 |
循環啟動中有復位命令 | ||
AL57 | 等待刀座及刀庫刀座刀具檢測報警 | 檢查開關 |
檢測到在等待刀座或刀庫刀座內有刀具處于異常狀態 | ||
AL58 | 零件記數結束 | |
根據預設數值零件記數完畢 | ||
單純報警狀態 | ||
AL60 | 主軸刀具夾緊/放松報警 | |
松開/夾緊操作沒有在10秒內完成 | 檢查有關零件(SL11,YV11) | |
松開操作限位開關/電磁閥故障 | ||
AL61 | 刀庫止動器進/出報警 | |
止動器進/出操作沒有在15秒內完成 | 檢查限位開關和閥(YV35,SL31,SL32) | |
限位開關或電磁閥故障 | ||
AL62 | ATC副手臂位置報警 | 檢查開關/閥(YV41,YV42,YV43,YV44,SX41,SX42,SX43) |
副手臂上/下沒有在25秒內完成 | ||
限位開關或電磁閥故障 | ||
AL63 | 副手臂進出報警 | |
副手臂進/出沒有在15秒內完成 | 檢查開關/閥(SL44,SL45,YV45) | |
限位開關或電磁閥故障 | ||
AL64 | 等待刀座主軸側/刀庫側報警 | |
等待刀座的移動沒有在15秒內完成 | 檢查開關/閥(SL45A,SL5B,YV5A) | |
限位開關或電磁閥故障 | ||
AL65 | ATC主換刀臂位置檢查報警 | |
ATC CAM沒在原點位置 | 檢測開關(SX51,SX52,SX53) | |
ATC 夾緊/放松開關沒有同步 | ||
AL67 | ATC 必須手動循環一次 | |
ATC 用手操作 | ATC 用手動完成一次循環 | |
AL68 | ATC門開/關報警 | |
門沒有在20秒內完成開/關 | 檢查開關/閥(SL56,SL57,YV5S,YV5C) | |
限位開關或電磁閥故障 | ||
AL69 | APC交換臂開/合報警 | |
APC交換臂沒有在25秒內完成 | 檢查開關/閥(SX71,SX73,YV71,YV72) | |
開關或電磁閥故障 | ||
AL70 | APC 手臂上/下報警 | |
APC 手臂上/下動作沒有在10秒內完成 | 檢查開關/閥(SX83,SX84,YV75,YV76) | |
開關或電磁閥故障 | ||
AL71 | APC 轉換臂180度CW/CCW報警 | |
APC 轉換臂180度CW/CCW沒有在25秒內完成 | 檢查開關/閥(SX81,SX82,YV73,YV74) | |
開關或電磁閥故障 | ||
AL72 | B軸轉臺夾緊/放松開關報警 | 檢查開關/閥(SP61,SL62,SP65,SP66,YV61,YV62,YV64) |
在NC檢測到夾緊的情況下,B軸卻是放松的。 | ||
夾緊放松的過程沒有在15秒內完成 | ||
開關或電磁閥故障 | ||
AL73 | 第5軸夾緊/放松開關報警 | |
第5軸夾緊/放松沒有在10秒內完成 | 檢查開關/閥(SL91,SL92,SV91) | |
開關或電磁閥故障 | ||
AL74 | ATC 超時 | |
T指令或M06沒有在45秒內完成 | 檢查ATC順序和有關開關 | |
開關或電磁閥故障 | ||
AL75 | ATC 刀庫轉動超時 | |
刀庫轉動沒有在230秒內完成 | 檢查相關開關(SX31,SX32 | |
開關或電磁閥故障 | ||
AL77 | 等待刀座和主軸刀具為0 | |
沒有等待刀座或主軸刀具數據 | 輸入刀具數據 | |
AL78 | ATC 面板操作手動開關打開狀態 | |
ATC 面板操作開關在手動位置 | 轉動開關到自動模式 | |
AL79 | 刀庫同步故障 | |
刀庫沒有保持同步 | 把刀庫旋轉一周 | |
(一號刀沒有找到) | 檢查限位開關(SX31) | |
檢測開關故障 | ||
AL80 | ATC或APC互鎖報警 | |
坐標軸不能移動 | ||
ATC手臂不在原點位置 | 初始化ATC/APC | |
APC手臂不在初始位置 | ||
AL81 | 刀庫門開 | |
刀庫門開 | 關門或檢測SL34開關 | |
開關壞 | ||
AL82 | 刀庫卸刀器報警 | |
手動刀具拉出開關打開狀態 | 檢查開關或閥(SL33,YV34) | |
開關故障 | ||
AL84 | APC準備工位門開著 | |
準備工位門開著 | 關門或檢查開關(S12) | |
開關故障 | ||
AL85 | 準備按鈕沒有按下 | |
在執行M60時按下準備按鈕 | 按下準備按鈕 | |
AL86 | APC面板手動開關被打開 | |
APC面板的模式開關被設置在手動位置 | 設置開關到自動模式 | |
AL87 | 主軸換檔失敗 | |
開電后沒有指令換檔命令 | 輸入S碼 | |
AL88 | 刀具監視器檢測到刀具破損 | 更換破損刀具 |
AL89 | 刀具監視器檢測到刀具磨損 | 更換磨損刀具 |
AL90 | B軸(工作臺)或工作臺夾緊報警 | 指令托盤或工作臺夾緊 |
在B軸放松的狀態下發出移動指令 | 檢查開關(SP61,SP62) | |
AL91 | 機械干涉報警 | |
機械的當前坐標在干涉區域 | 移動坐標到自由區域 | |
AL92 | APC止動器進/出報警 | 檢查開關或閥(SX87,SX88,YV84,YV85) |
APC止動器進/出沒有在20秒內完成 | ||
開關或電磁閥故障 | ||
AL93 | 手動坐標軸移動互鎖報警 | |
JOG模式進給坐標軸互鎖 | 解除坐標軸互鎖狀態 | |
機床已經在原點位置又發出原點復歸指令 | 執行原點復歸-方向操作 | |
AL94 | 排屑機或螺旋排屑機報警 | |
輸送電機過載 | 檢查排屑機 | |
AL95 | 進給倍率為0 | |
G01速度調整開關被調整到0 | 檢查開關 | |
AL96 | 自動電源關準備 | 檢查自動電源關的撥動開關 |
AL97 | 機床鎖定開關處于就緒狀態 | |
機床鎖定開關開 | 檢查開關 | |
輔助鎖定開關開 |